Zenith Coordinate Measuring Machine

CMZ Zenith Coordinate Measuring Machine is a high-end metrological equipment produced by TZTEK. It has a fixed-bridge structure to meet the requirements of ultra-high precision measurement of complex components. With advantages of sub-micron accuracy, high efficiency and stable performance, it contributes to precision machining, assembly and quality control.

Description

Features

Ultra-high rigid mechanical structure

The high-rigid fixed-bridge mechanical structure, as well as the combination of granite beams, granite bases, granite columns and Z-axie made of industrial precision material silicon carbide ceramic, ensures the high stability of the mechanical structure and the strong resistance against external interference.

Ultra-high stability

  • Preloaded air bearings are used for all axes, and their enveloping structure ensures high rigidity, no contact and low friction.
  • Zero expansion coefficient scale, ultra-high resolution up to the nanometer level, and insusceptible to external temperature, ensures high precision and the stablity of the machine.

In-house compensation algorithm

With TZTEK in-house geometric error compensation, the accuracy can reach metrology grade.

Specification

ModelStroke range(mm)Overall dimension(mm)Main machine weight(kg)Max. load (kg)Vector motion velocity (mm/s)Vector motion acceleration (mm/s2)
XYZLXLYLZ
06.08.0660080060016822107326047574005201870
08.10.06800100060018822557326062075005201870
10.12.081000120080020823007366080008005201870
10.15.081000150080020823582366096008005201870
12.15.101200150010002282350740601080010004001000
12.20.101200200010002282463240601380010004001000
Length measurement errorMPE (EO) (µm)Single stylus form probing errorMPE (PFTU) (µm)
From 0.6+L/400From 0.6
Precision index: According to the performance evaluation standard of CMM in ISO10360-2:2009 and ISO10360-5:2010
Temperature requirements for measuring machine roomPower requirement
Room temperature (temperature control room)20°±1°CVoltage220 vac±10%
Temperature gradient (time)0.5°C /hFrequency50/60 Hz±1%
Temperature gradient (time)1°C /24hElectric current6A
Temperature gradient (space)0.5°C/mPower1.5kw
Air source requirementElectrical equipment requires reliable grounding: grounding resistance is less than 4 ohms
Min. air supply pressure0.6MPaHumidity requirements for measuring machine room
Air consumption250NL/minRelative air humidity25~75%